Controlled environments

Food and nutraceutical high care areas

Food manufacturers are audited by their customers, and the audit has been getting harder for years. A high care zone built to pharmaceutical discipline passes those audits comfortably. One built to general commercial standard usually does not.

Home › Controlled environments › Food and nutraceutical high care

Who this is for

Food manufacturers running ready to eat or post process products, dairy and beverage processors, nutraceutical and supplement manufacturers, pet food producers, and export registered establishments whose facility has to satisfy an overseas regulator as well as a domestic one.

The common thread is that somebody else decides whether your building is good enough. Sometimes that is a regulator. More often it is a major customer's auditor, arriving with a scheme checklist and a camera.

Why we are in this market

Because a high care food zone and a GMP cleanroom are the same building problem with different paperwork.

The requirementPharmaceuticalHigh care food
Separation of clean from less cleanClassified zones and airlocksHigh care and low care segregation
Air moving the right directionPressure cascadePositive pressure to high care
People change before enteringGowning sequenceHygiene entry, boot wash, handwash
Cleanable surfaces with no trapsCoved, non shedding finishesHygienic finishes, coved, sealed
Controlled material flowPass throughs and airlocksProduct and waste segregation

Nobody in this market is offering food manufacturers a builder who works to pharmaceutical discipline. That is the whole proposition.

What we build

  • High care and high risk zones, with the envelope, the airflow and the entry sequence that make the zone real rather than notional
  • Allergen segregation, which is usually a flow and a fabric problem at the same time
  • Hygienic fitout, wall and ceiling systems, coving, drainage falls and the junction details that auditors photograph
  • Hygiene entry points, boot washes, hand wash stations and the physical arrangement that makes bypassing them awkward
  • Packing halls and post process areas where the product is exposed after the kill step
  • Chillers, freezers and temperature controlled process rooms

The details that fail audits

In our experience the findings are rarely about the big things. They are about the same short list of construction details, over and over.

  • Floor to wall junctions that are not properly coved, or coved in a material that has cracked
  • Drainage that does not fall where it needs to, so water sits
  • Penetrations sealed with something that has perished and now harbours soil
  • Ceiling voids that are open to the production area
  • Condensation on overhead services above exposed product
  • Doors that no longer seal, so the pressure regime is theoretical

All construction. All avoidable at the specification stage, and all expensive once the line is running.